Hornet and Bee Installation Guide Technical Specifications
MAN-HRBEIG (Ver. 1.3)
www.elmomc.com
59
4.3.2. Bee
Feature Units 3/60 2.5/100
Minimum supply voltage VDC 7.5 12
Nominal supply voltage VDC 50 85
Maximum supply voltage VDC 59 95
Maximum continuous power output W 160 200
Efficiency at rated power (at nominal conditions) % > 99
Maximum output voltage 95% of DC bus voltage at
f=22 kHz
Auxiliary power supply VDC 11 to 95 VDC (up to 2.5 VA inc.
5 V/200 mA for encoder)
Amplitude sinusoidal/DC continuous current (Ic) A 3.3 2.5
Sinusoidal continuous RMS current limit (Ic) A 2.3 1.8
Peak current limit A 2 x Ic
Weight g (oz) 27 g (0.95 oz)
Dimensions mm (in) 51 x 12.5 x 42 (2" x 0.49" x 1.65")
Digital in/Digital out/Analog in 6/2/1
Mounting method PCB mount
4.3.3. Auxiliary Supply
Feature Details
Auxiliary power supply Isolated DC source only
Auxiliary supply input voltage 12 VDC to 95 VDC
Auxiliary supply input power <2.5 VA (this includes the 5 V/200 mA load for
the main encoder only)