Elmo ExtrIQ line Installation Guide Page 70

  • Download
  • Add to my manuals
  • Print
  • Page
    / 73
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 69
Hornet and Bee Installation Guide Technical Specifications
MAN-HRBEIG (Ver. 1.3)
www.elmomc.com
70
4.7.2. Digital Output Interface
Feature Details
Type of output
Optically isolated
Open collector and open emitter
Maximum supply output (Vcc) 30 V
Max. output current
Iout (max) (Vout = Low)
Iout (max) ≤ 10 mA
VOL at maximum output voltage (low
level)
Vout (on) 0.3 V
RL External resistor RL must be selected to limit output
current to no more than 10 mA.
(max)
Io
VOL
Vcc
R
L
=
Executable time If output is set to one of the built-in functions
Home flag, Brake or AOK execution is immediate
upon detection:
0 < T < 4 x TS
If output is set to General output and is executed
from a program, the typical time is approximately
0.5 msec.
Figure 37: Digital Output Schematic
4.7.3. Analog Input
Feature Details
Maximum operating differential voltage ± 10 V
Maximum absolute differential input voltage ± 16 V
Differential input resistance 3.74 kΩ
Analog input command resolution 14-bit